The GET-MAX 1 Megawatt Microwave Generator is a combined unit of 915MHz generators working as one system, for outdoor industrial processing. By combining several microwave power units into one, the GET-MAX serves as a cost-efficient generator solution. All units are modular, custom-built for each process, application, or environment.
1 Megawatt Microwave Generator: GET-MAX Overview
The 1 Megawatt Microwave Generator GET-MAX system integrates multiple power supplies with system controls into one package. It is best suited for large-scale, outdoor industrial applications requiring high microwave power levels.
The GET-MAX system equipment consists of:
- Microwave circulator assemblies (10 x 100 kW)
- Water-cooled microwave generators (10 x 100 kW)
- WR-975 waveguide flange connections (10 x 100 kW)
- Allen Bradley Ethernet-based control hardware
- Allen Bradley Panelview Plus operator interface
- Control signal outputs and inputs via weatherproof connection panel
- Internal plumbing such that a single water supply and return are required for the container
- Spares list
- Service lights
- Waveguide blower fans
- Container air conditioner
- Software for controlling the generator system
- Instruction and service manuals: schematic diagrams and installation instructions
GET-MAX Control System
The control system shall carry out all functions for safe and optimum operation of the microwave generators and associated equipment autonomously. It shall incorporate any features required for test and maintenance.
In addition, the control system shall:
- Provide for remote start-up and shut-down of the system
- Provide for remote emergency stop and power isolation
- Accept a power demand signal from a remote controller
- Arc quench command
- As a minimum, the system shall report to the remote controller:
- System status (monitor system health and parameters trends)
- Actual output power for each generator
- Reflected power for each generator
- System shall allow the output of each generator to be varied between 20% and 100% rated power
1 Megawatt GET-MAX Generator Specifications
POWER OUTPUT | |
Microwave Frequency: | 915 MHz |
Configuration (Max.): | 10 generators @ 100 kW = 1 Megawatt |
Configuration (Min.): | 6 generators @ 100 kW = 600 kilowatts |
UTILITY REQUIREMENTS | |
Electrical | |
Ambient Temp. (°F): | 40 – 100 |
Electrical Service: | 1400 KVA @ 575V, 60 Hz, 3 Phase |
Electrical Load: | 1.4 MW |
Current Draw, 575V: | 1500 FLA max |
Cooling Water | |
Flow: | 120 GPM min |
Supply Pressure: | 100 PSI max |
Return Pressure: | 25 PSI max |
Temp. (°F): | 50 – 70 |
Particle Size: | 50 Micron max |
PH: | 6.8 – 7.2 |
Propylene Glycol Requirement (burst protection) | |
-20°F to 32°F ambient temperatures: | 30% by weight |
Above 32°F ambient temperatures: | none, use pure water |
CONTROLS | |
Integrated PLC: | Allen-Bradley Compact Logix |
Operator Interface: | Allen-Bradley Panelview Plus |
REGULATORY COMPLIANCE | |
Underwriter’s Laboratory: | UL923, UL508A |
National Fire Protection Agency: | NFPA70 |